<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>AMSYSCO Post Tension Blog &#187; stressing</title>
	<atom:link href="http://www.amsyscoinc.com/blog/tag/stressing/feed/" rel="self" type="application/rss+xml" />
	<link>http://www.amsyscoinc.com/blog</link>
	<description>Post-Tensioning for Concrete Contractors, Structural Engineers and Architects</description>
	<lastBuildDate>Thu, 19 Jan 2012 20:45:35 +0000</lastBuildDate>
	<language>en</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
	<generator>http://wordpress.org/?v=3.3.1</generator>
		<item>
		<title>Missed Stressing Operation</title>
		<link>http://www.amsyscoinc.com/blog/2011/12/18/missed-stressing-operation/</link>
		<comments>http://www.amsyscoinc.com/blog/2011/12/18/missed-stressing-operation/#comments</comments>
		<pubDate>Sun, 18 Dec 2011 17:00:51 +0000</pubDate>
		<dc:creator>nkhosa</dc:creator>
				<category><![CDATA[Field Issues]]></category>
		<category><![CDATA[elongation]]></category>
		<category><![CDATA[Post Tension]]></category>
		<category><![CDATA[stressing]]></category>

		<guid isPermaLink="false">http://www.amsyscoinc.com/blog/?p=2301</guid>
		<description><![CDATA[What happens if you forgot to stress an unbonded post-tensioning tendon at the construction joint and have already poured the subsequent pour? <span style="color:#777"> . . . &#8594; Read More: <a href="http://www.amsyscoinc.com/blog/2011/12/18/missed-stressing-operation/">Missed Stressing Operation</a></span>]]></description>
			<content:encoded><![CDATA[<p><strong>Q:</strong> What happens if you forgot to stress an unbonded post-tensioning tendon at the construction joint and have already poured the subsequent pour?</p>
<p><strong>A:</strong> The most preferred option is to stress the tendon in the subsequent pour.  However, the following items should be factored in:</p>
<p><strong>a) The 7% Elongation Range must be revised.</strong></p>
<p>Since you have a longer pull, the <a class="vt-p" href="http://www.amsyscoinc.com/blog/2010/01/29/material-properties-of-post-tension-strands/">elongation calculation</a> needs to be revised also.  This should be noted in the elongation records from the PTI-Certified Inspector.  A thumb-rule is to just add Min1+Min2 and Max1+Max2 together.  For example,</p>
<ul>
<li>First pull of 50&#8242; would be Min1 = 3.72&#8243; and Max1 = 4.28&#8243;</li>
<li>Second pull of 100&#8242; would be Min1 = 7.44&#8243; and Max1 = 8.56&#8243;</li>
<li>New elongation range for 150&#8242; pull would be Min1 = 3.72&#8243; + 7.44&#8243; = 11.16&#8243; and Max1 = 12.84&#8243;.</li>
<li>The new range is an <em>close approximation</em>.  A more accurate range can be calculated with <a class="vt-p" href="http://www.amsyscoinc.com/blog/2011/03/10/post-tension-friction-loss-calculations/">PT software</a>.  This is especially important for very long pulls.</li>
</ul>
<p><strong>b) The force in the tendon will likely be less.</strong></p>
<p>Since the stressed tendon length is now longer, your angular and wobble friction have likely increased somewhat due to the increased number of spans.  In other words, the final average force will drop <span style="text-decoration: underline;">in both pours</span> for that particular tendon.</p>
<ul>
<li>Previously, the 50&#8242; pull may provide 27.5 kips of force in Pour #1.</li>
<li>Previously, the 100&#8242; pull may provide 27.3 kips of force in Pour #2.</li>
<li>Now, the 150&#8242; pull may provide only 26.9 kips of force in Pours #1 and #2.</li>
</ul>
<p><strong>c) The intermediate anchor has been abandoned.</strong></p>
<p>The force within the 150&#8242; tendon will be transmitted uniformly through the construction joint.  Conversely, the 50&#8242; tendon transmits force only within Pour #1 and the 100&#8242; tendon transmits force only within Pour #2 (i.e. the construction joint &#8220;locks-off&#8221; the force within each pour).  This is important should be there be any repair/renovation conducted in the future.</p>
<p>- Neel Khosa, Vice President, AMSYSCO</p>
<p>____________________________________________</p>
<div style="text-align: left;"><strong>Copyright © 2011 by </strong><a class="vt-p" onclick="pageTracker._trackPageview('/outbound/article/bit.ly');" href="http://bit.ly/1tEis" target="_blank"><strong>AMSYSCO, Inc.</strong></a><strong> All rights reserved.</strong></div>
<div style="text-align: left;"><strong><br />
</strong></div>
]]></content:encoded>
			<wfw:commentRss>http://www.amsyscoinc.com/blog/2011/12/18/missed-stressing-operation/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Video : Stressing Unbonded Post Tension Tendon</title>
		<link>http://www.amsyscoinc.com/blog/2011/06/16/video-stressing-unbonded-post-tension-tendon/</link>
		<comments>http://www.amsyscoinc.com/blog/2011/06/16/video-stressing-unbonded-post-tension-tendon/#comments</comments>
		<pubDate>Thu, 16 Jun 2011 23:31:35 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Field Issues]]></category>
		<category><![CDATA[Video]]></category>
		<category><![CDATA[stressing]]></category>
		<category><![CDATA[YouTube Video]]></category>

		<guid isPermaLink="false">http://www.amsyscoinc.com/blog/?p=2052</guid>
		<description><![CDATA[<p>This short video show the stressing an unbonded post-tensioning tendon with a hydraulic jack (8-inch stroke). This tendon was roughly 130 feet long so it required two strokes. The elongation for a 100-foot-long tendon is roughly 8 inches. Refer to the Post-Tensioning Institute&#8217;s &#8220;Field Procedures Manual for Unbonded Single-Strand Tendons&#8221; Chapter 6 for additional information.</p> <span style="color:#777"> . . . &#8594; Read More: <a href="http://www.amsyscoinc.com/blog/2011/06/16/video-stressing-unbonded-post-tension-tendon/">Video : Stressing Unbonded Post Tension Tendon</a></span>]]></description>
			<content:encoded><![CDATA[<p>This short video show the stressing an unbonded post-tensioning tendon with a hydraulic jack (8-inch stroke). This tendon was roughly 130 feet long so it required two strokes. The elongation for a 100-foot-long tendon is roughly 8 inches. Refer to the Post-Tensioning Institute&#8217;s &#8220;Field Procedures Manual for Unbonded Single-Strand Tendons&#8221; Chapter 6 for additional information.</p>
<p><object width="450" height="400" classid="clsid:d27cdb6e-ae6d-11cf-96b8-444553540000" codebase="http://download.macromedia.com/pub/shockwave/cabs/flash/swflash.cab#version=6,0,40,0"><param name="allowFullScreen" value="true" /><param name="allowscriptaccess" value="always" /><param name="src" value="http://www.youtube.com/v/rNJGaiGYzAc?version=3&amp;hl=en_US" /><param name="allowfullscreen" value="true" /><embed width="450" height="400" type="application/x-shockwave-flash" src="http://www.youtube.com/v/rNJGaiGYzAc?version=3&amp;hl=en_US" allowFullScreen="true" allowscriptaccess="always" allowfullscreen="true" /></object><br />
_________________________________________________</p>
<div style="text-align: left;"><strong>Copyright © 2011 by </strong><a class="vt-p" onclick="pageTracker._trackPageview('/outbound/article/bit.ly');" href="http://bit.ly/1tEis" target="_blank"><strong>AMSYSCO, Inc.</strong></a><strong> All rights reserved.</strong></div>
<p><!--[if IE]><iframe frameborder="0" allowTransparency="true" class="addtoany_special_service google_plusone" src="https://plusone.google.com/u/0/_/%2B1/fastbutton?url=http%3A%2F%2Fwww.amsyscoinc.com%2Fblog%2F2011%2F06%2F16%2Fvideo-stressing-unbonded-post-tension-tendon%2F&amp;size=medium&amp;count=true" scrolling="no" style="border:none;overflow:hidden;width:90px;height:20px"></iframe><![endif]--><!--[if !IE]><!--><iframe class="addtoany_special_service google_plusone" src="https://plusone.google.com/u/0/_/%2B1/fastbutton?url=http%3A%2F%2Fwww.amsyscoinc.com%2Fblog%2F2011%2F06%2F16%2Fvideo-stressing-unbonded-post-tension-tendon%2F&amp;size=medium&amp;count=true" scrolling="no" style="border:none;overflow:hidden;width:90px;height:20px"></iframe><!--<![endif]--><!--[if IE]><iframe frameborder="0" allowTransparency="true" class="addtoany_special_service facebook_like" src="http://www.facebook.com/plugins/like.php?href=http%3A%2F%2Fwww.amsyscoinc.com%2Fblog%2F2011%2F06%2F16%2Fvideo-stressing-unbonded-post-tension-tendon%2F&amp;layout=button_count&amp;show_faces=false&amp;width=75&amp;action=like&amp;colorscheme=light&amp;height=20&amp;ref=addtoany" scrolling="no" style="border:none;overflow:hidden;width:90px;height:21px"></iframe><![endif]--><!--[if !IE]><!--><iframe class="addtoany_special_service facebook_like" src="http://www.facebook.com/plugins/like.php?href=http%3A%2F%2Fwww.amsyscoinc.com%2Fblog%2F2011%2F06%2F16%2Fvideo-stressing-unbonded-post-tension-tendon%2F&amp;layout=button_count&amp;show_faces=false&amp;width=75&amp;action=like&amp;colorscheme=light&amp;height=20&amp;ref=addtoany" scrolling="no" style="border:none;overflow:hidden;width:90px;height:21px"></iframe><!--<![endif]--><!--[if IE]><iframe frameborder="0" allowTransparency="true" class="addtoany_special_service twitter_tweet" src="http://platform.twitter.com/widgets/tweet_button.html?url=http%3A%2F%2Fwww.amsyscoinc.com%2Fblog%2F2011%2F06%2F16%2Fvideo-stressing-unbonded-post-tension-tendon%2F&amp;counturl=http%3A%2F%2Fwww.amsyscoinc.com%2Fblog%2F2011%2F06%2F16%2Fvideo-stressing-unbonded-post-tension-tendon%2F&amp;count=horizontal&amp;text=Video%20%3A%20Stressing%20Unbonded%20Post%20Tension%20Tendon" scrolling="no" style="border:none;overflow:hidden;width:130px;height:20px"></iframe><![endif]--><!--[if !IE]><!--><iframe class="addtoany_special_service twitter_tweet" src="http://platform.twitter.com/widgets/tweet_button.html?url=http%3A%2F%2Fwww.amsyscoinc.com%2Fblog%2F2011%2F06%2F16%2Fvideo-stressing-unbonded-post-tension-tendon%2F&amp;counturl=http%3A%2F%2Fwww.amsyscoinc.com%2Fblog%2F2011%2F06%2F16%2Fvideo-stressing-unbonded-post-tension-tendon%2F&amp;count=horizontal&amp;text=Video%20%3A%20Stressing%20Unbonded%20Post%20Tension%20Tendon" scrolling="no" style="border:none;overflow:hidden;width:130px;height:20px"></iframe><!--<![endif]--><a class="a2a_dd a2a_target addtoany_share_save" href="http://www.addtoany.com/share_save#url=http%3A%2F%2Fwww.amsyscoinc.com%2Fblog%2F2011%2F06%2F16%2Fvideo-stressing-unbonded-post-tension-tendon%2F&amp;title=Video%20%3A%20Stressing%20Unbonded%20Post%20Tension%20Tendon" id="wpa2a_2">SHARE THIS</a></p>]]></content:encoded>
			<wfw:commentRss>http://www.amsyscoinc.com/blog/2011/06/16/video-stressing-unbonded-post-tension-tendon/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Video : Applying paint mark for Tendon Elongation</title>
		<link>http://www.amsyscoinc.com/blog/2011/06/16/applying-paint-mark-for-tendon-elongation/</link>
		<comments>http://www.amsyscoinc.com/blog/2011/06/16/applying-paint-mark-for-tendon-elongation/#comments</comments>
		<pubDate>Thu, 16 Jun 2011 23:17:34 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Field Issues]]></category>
		<category><![CDATA[Video]]></category>
		<category><![CDATA[elongation]]></category>
		<category><![CDATA[paint marks]]></category>
		<category><![CDATA[Post Tension]]></category>
		<category><![CDATA[stressing]]></category>

		<guid isPermaLink="false">http://www.amsyscoinc.com/blog/?p=2040</guid>
		<description><![CDATA[<p>This short clip shows how to apply paint-marks prior to stressing of post-tension tendons. It&#8217;s recommended to use a straight-edge, metal to help with elongation measurements. Refer to the Post-Tensioning Institute&#8217;s &#8220;Field Procedures Manual for Unbonded Single-Strand Tendons&#8221; Chapter 7 for additional information. _________________________________________________</p> Copyright © 2011 by AMSYSCO, Inc. All rights reserved. <p> </p> <span style="color:#777"> . . . &#8594; Read More: <a href="http://www.amsyscoinc.com/blog/2011/06/16/applying-paint-mark-for-tendon-elongation/">Video : Applying paint mark for Tendon Elongation</a></span>]]></description>
			<content:encoded><![CDATA[<p>This short clip shows how to apply paint-marks prior to stressing of post-tension tendons. It&#8217;s recommended to use a straight-edge, metal to help with elongation measurements.  Refer to the Post-Tensioning Institute&#8217;s &#8220;Field Procedures Manual for Unbonded Single-Strand Tendons&#8221; Chapter 7 for additional information.<br />
<object width="450" height="405"><param name="movie" value="http://www.youtube.com/v/mJi_tibckZc?version=3&amp;hl=en_US" /><param name="allowFullScreen" value="true" /><param name="allowscriptaccess" value="always" /><embed type="application/x-shockwave-flash" width="450" height="405" src="http://www.youtube.com/v/mJi_tibckZc?version=3&amp;hl=en_US" allowfullscreen="true" allowscriptaccess="always"></embed></object><br />
_________________________________________________</p>
<div style="text-align: left;"><strong>Copyright © 2011 by </strong><a class="vt-p" onclick="pageTracker._trackPageview('/outbound/article/bit.ly');" href="http://bit.ly/1tEis" target="_blank"><strong>AMSYSCO, Inc.</strong></a><strong> All rights reserved.</strong></div>
<div style="text-align: left;">
<p><strong> </strong></p>
<p><strong> </strong></p>
</div>
<p><!--[if IE]><iframe frameborder="0" allowTransparency="true" class="addtoany_special_service google_plusone" src="https://plusone.google.com/u/0/_/%2B1/fastbutton?url=http%3A%2F%2Fwww.amsyscoinc.com%2Fblog%2F2011%2F06%2F16%2Fapplying-paint-mark-for-tendon-elongation%2F&amp;size=medium&amp;count=true" scrolling="no" style="border:none;overflow:hidden;width:90px;height:20px"></iframe><![endif]--><!--[if !IE]><!--><iframe class="addtoany_special_service google_plusone" src="https://plusone.google.com/u/0/_/%2B1/fastbutton?url=http%3A%2F%2Fwww.amsyscoinc.com%2Fblog%2F2011%2F06%2F16%2Fapplying-paint-mark-for-tendon-elongation%2F&amp;size=medium&amp;count=true" scrolling="no" style="border:none;overflow:hidden;width:90px;height:20px"></iframe><!--<![endif]--><!--[if IE]><iframe frameborder="0" allowTransparency="true" class="addtoany_special_service facebook_like" src="http://www.facebook.com/plugins/like.php?href=http%3A%2F%2Fwww.amsyscoinc.com%2Fblog%2F2011%2F06%2F16%2Fapplying-paint-mark-for-tendon-elongation%2F&amp;layout=button_count&amp;show_faces=false&amp;width=75&amp;action=like&amp;colorscheme=light&amp;height=20&amp;ref=addtoany" scrolling="no" style="border:none;overflow:hidden;width:90px;height:21px"></iframe><![endif]--><!--[if !IE]><!--><iframe class="addtoany_special_service facebook_like" src="http://www.facebook.com/plugins/like.php?href=http%3A%2F%2Fwww.amsyscoinc.com%2Fblog%2F2011%2F06%2F16%2Fapplying-paint-mark-for-tendon-elongation%2F&amp;layout=button_count&amp;show_faces=false&amp;width=75&amp;action=like&amp;colorscheme=light&amp;height=20&amp;ref=addtoany" scrolling="no" style="border:none;overflow:hidden;width:90px;height:21px"></iframe><!--<![endif]--><!--[if IE]><iframe frameborder="0" allowTransparency="true" class="addtoany_special_service twitter_tweet" src="http://platform.twitter.com/widgets/tweet_button.html?url=http%3A%2F%2Fwww.amsyscoinc.com%2Fblog%2F2011%2F06%2F16%2Fapplying-paint-mark-for-tendon-elongation%2F&amp;counturl=http%3A%2F%2Fwww.amsyscoinc.com%2Fblog%2F2011%2F06%2F16%2Fapplying-paint-mark-for-tendon-elongation%2F&amp;count=horizontal&amp;text=Video%20%3A%20Applying%20paint%20mark%20for%20Tendon%20Elongation" scrolling="no" style="border:none;overflow:hidden;width:130px;height:20px"></iframe><![endif]--><!--[if !IE]><!--><iframe class="addtoany_special_service twitter_tweet" src="http://platform.twitter.com/widgets/tweet_button.html?url=http%3A%2F%2Fwww.amsyscoinc.com%2Fblog%2F2011%2F06%2F16%2Fapplying-paint-mark-for-tendon-elongation%2F&amp;counturl=http%3A%2F%2Fwww.amsyscoinc.com%2Fblog%2F2011%2F06%2F16%2Fapplying-paint-mark-for-tendon-elongation%2F&amp;count=horizontal&amp;text=Video%20%3A%20Applying%20paint%20mark%20for%20Tendon%20Elongation" scrolling="no" style="border:none;overflow:hidden;width:130px;height:20px"></iframe><!--<![endif]--><a class="a2a_dd a2a_target addtoany_share_save" href="http://www.addtoany.com/share_save#url=http%3A%2F%2Fwww.amsyscoinc.com%2Fblog%2F2011%2F06%2F16%2Fapplying-paint-mark-for-tendon-elongation%2F&amp;title=Video%20%3A%20Applying%20paint%20mark%20for%20Tendon%20Elongation" id="wpa2a_4">SHARE THIS</a></p>]]></content:encoded>
			<wfw:commentRss>http://www.amsyscoinc.com/blog/2011/06/16/applying-paint-mark-for-tendon-elongation/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>How do I know if my Post-Tensioning Tendons have been stressed?</title>
		<link>http://www.amsyscoinc.com/blog/2011/06/16/how-do-i-know-if-my-post-tensioning-tendons-have-been-stressed/</link>
		<comments>http://www.amsyscoinc.com/blog/2011/06/16/how-do-i-know-if-my-post-tensioning-tendons-have-been-stressed/#comments</comments>
		<pubDate>Thu, 16 Jun 2011 22:32:20 +0000</pubDate>
		<dc:creator>nkhosa</dc:creator>
				<category><![CDATA[Field Issues]]></category>
		<category><![CDATA[bitemarks]]></category>
		<category><![CDATA[elongation]]></category>
		<category><![CDATA[paint marks]]></category>
		<category><![CDATA[Post Tensioning]]></category>
		<category><![CDATA[stressing]]></category>

		<guid isPermaLink="false">http://www.amsyscoinc.com/blog/?p=2032</guid>
		<description><![CDATA[<p>As a post-tensioning inspector or installer, have you ever been in a situation whether you are unsure whether some PT tendons have been stressed?  By not having a PT tendon stressed, this could have detrimental effects on the structure.</p> <p>Here are three pointers that may help you out:</p> <p>1. PAINT-MARKS : Compare the location of the <span style="color:#777"> . . . &#8594; Read More: <a href="http://www.amsyscoinc.com/blog/2011/06/16/how-do-i-know-if-my-post-tensioning-tendons-have-been-stressed/">How do I know if my Post-Tensioning Tendons have been stressed?</a></span>]]></description>
			<content:encoded><![CDATA[<p>As a post-tensioning inspector or installer, have you ever been in a situation whether you are unsure whether some PT tendons have been stressed?  By not having a PT tendon stressed, this could have detrimental effects on the structure.</p>
<p>Here are three pointers that may help you out:</p>
<p>1. <strong>PAINT-MARKS</strong> : Compare the location of the paint-marks to other tendons of the <span style="text-decoration: underline;">same length</span>.  If you see a major difference in one or more paint-marks, then the flag should go up.  If the location of the paint marks are similar, then either ALL of tendon have been stressed or NONE of them have been stressed.  If you have a deviation, then you may have an unstressed tendons or an elongation issue.  (Related Video : <a class="vt-p" href="http://www.amsyscoinc.com/blog/2011/06/16/applying-paint-mark-for-tendon-elongation/">Applying paint mark for post-tensioning tendon</a>).</p>
<p>2. <strong>BITE-MARKS</strong> : Check whether there are &#8220;bite-marks&#8221; on the tendons.  During the stressing operation, the hydraulic jack &#8220;grabs&#8221; the stressing tail of the PT strand and and creates a series of small bite-marks. The picture below shows two tendons that have been stressed (<em>click picture to enlarge</em>).  This visual inspection helps if your paint-marks have been washed away.</p>
<div id="attachment_2033" class="wp-caption aligncenter" style="width: 310px"><a class="vt-p" href="http://www.amsyscoinc.com/blog/wp-content/uploads/2011/06/DSCN0952.jpg"><img class="size-medium wp-image-2033" title="PT Bitemark" src="http://www.amsyscoinc.com/blog/wp-content/uploads/2011/06/DSCN0952-300x225.jpg" alt="" width="300" height="225" /></a><p class="wp-caption-text">Bitemarks into Post-Tensioning Strand</p></div>
<p>3. <strong>ELONGATION RECORDING</strong> : AMSYSCO <span style="text-decoration: underline;">highly </span>recommends that the inspector (or testing agency) record elongation during the stressing operations&#8230;rather than several hours later.  This step increases the quality control of the project and eliminates a potential unstressed tendon.</p>
<p>- Neel Khosa, Vice President, AMSYSCO</p>
<p>_________________________________________________</p>
<div style="text-align: left;"><strong>Copyright © 2011 by </strong><a class="vt-p" onclick="pageTracker._trackPageview('/outbound/article/bit.ly');" href="http://bit.ly/1tEis" target="_blank"><strong>AMSYSCO, Inc.</strong></a><strong> All rights reserved.</strong></div>
<p><!--[if IE]><iframe frameborder="0" allowTransparency="true" class="addtoany_special_service google_plusone" src="https://plusone.google.com/u/0/_/%2B1/fastbutton?url=http%3A%2F%2Fwww.amsyscoinc.com%2Fblog%2F2011%2F06%2F16%2Fhow-do-i-know-if-my-post-tensioning-tendons-have-been-stressed%2F&amp;size=medium&amp;count=true" scrolling="no" style="border:none;overflow:hidden;width:90px;height:20px"></iframe><![endif]--><!--[if !IE]><!--><iframe class="addtoany_special_service google_plusone" src="https://plusone.google.com/u/0/_/%2B1/fastbutton?url=http%3A%2F%2Fwww.amsyscoinc.com%2Fblog%2F2011%2F06%2F16%2Fhow-do-i-know-if-my-post-tensioning-tendons-have-been-stressed%2F&amp;size=medium&amp;count=true" scrolling="no" style="border:none;overflow:hidden;width:90px;height:20px"></iframe><!--<![endif]--><!--[if IE]><iframe frameborder="0" allowTransparency="true" class="addtoany_special_service facebook_like" src="http://www.facebook.com/plugins/like.php?href=http%3A%2F%2Fwww.amsyscoinc.com%2Fblog%2F2011%2F06%2F16%2Fhow-do-i-know-if-my-post-tensioning-tendons-have-been-stressed%2F&amp;layout=button_count&amp;show_faces=false&amp;width=75&amp;action=like&amp;colorscheme=light&amp;height=20&amp;ref=addtoany" scrolling="no" style="border:none;overflow:hidden;width:90px;height:21px"></iframe><![endif]--><!--[if !IE]><!--><iframe class="addtoany_special_service facebook_like" src="http://www.facebook.com/plugins/like.php?href=http%3A%2F%2Fwww.amsyscoinc.com%2Fblog%2F2011%2F06%2F16%2Fhow-do-i-know-if-my-post-tensioning-tendons-have-been-stressed%2F&amp;layout=button_count&amp;show_faces=false&amp;width=75&amp;action=like&amp;colorscheme=light&amp;height=20&amp;ref=addtoany" scrolling="no" style="border:none;overflow:hidden;width:90px;height:21px"></iframe><!--<![endif]--><!--[if IE]><iframe frameborder="0" allowTransparency="true" class="addtoany_special_service twitter_tweet" src="http://platform.twitter.com/widgets/tweet_button.html?url=http%3A%2F%2Fwww.amsyscoinc.com%2Fblog%2F2011%2F06%2F16%2Fhow-do-i-know-if-my-post-tensioning-tendons-have-been-stressed%2F&amp;counturl=http%3A%2F%2Fwww.amsyscoinc.com%2Fblog%2F2011%2F06%2F16%2Fhow-do-i-know-if-my-post-tensioning-tendons-have-been-stressed%2F&amp;count=horizontal&amp;text=How%20do%20I%20know%20if%20my%20Post-Tensioning%20Tendons%20have%20been%20stressed%3F" scrolling="no" style="border:none;overflow:hidden;width:130px;height:20px"></iframe><![endif]--><!--[if !IE]><!--><iframe class="addtoany_special_service twitter_tweet" src="http://platform.twitter.com/widgets/tweet_button.html?url=http%3A%2F%2Fwww.amsyscoinc.com%2Fblog%2F2011%2F06%2F16%2Fhow-do-i-know-if-my-post-tensioning-tendons-have-been-stressed%2F&amp;counturl=http%3A%2F%2Fwww.amsyscoinc.com%2Fblog%2F2011%2F06%2F16%2Fhow-do-i-know-if-my-post-tensioning-tendons-have-been-stressed%2F&amp;count=horizontal&amp;text=How%20do%20I%20know%20if%20my%20Post-Tensioning%20Tendons%20have%20been%20stressed%3F" scrolling="no" style="border:none;overflow:hidden;width:130px;height:20px"></iframe><!--<![endif]--><a class="a2a_dd a2a_target addtoany_share_save" href="http://www.addtoany.com/share_save#url=http%3A%2F%2Fwww.amsyscoinc.com%2Fblog%2F2011%2F06%2F16%2Fhow-do-i-know-if-my-post-tensioning-tendons-have-been-stressed%2F&amp;title=How%20do%20I%20know%20if%20my%20Post-Tensioning%20Tendons%20have%20been%20stressed%3F" id="wpa2a_6">SHARE THIS</a></p>]]></content:encoded>
			<wfw:commentRss>http://www.amsyscoinc.com/blog/2011/06/16/how-do-i-know-if-my-post-tensioning-tendons-have-been-stressed/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Informational Presentation about Post-Tensioned Concrete for Contractors</title>
		<link>http://www.amsyscoinc.com/blog/2010/10/23/informational-presentation-for-contractors/</link>
		<comments>http://www.amsyscoinc.com/blog/2010/10/23/informational-presentation-for-contractors/#comments</comments>
		<pubDate>Sat, 23 Oct 2010 23:42:47 +0000</pubDate>
		<dc:creator>nkhosa</dc:creator>
				<category><![CDATA[Field Issues]]></category>
		<category><![CDATA[Post Tension]]></category>
		<category><![CDATA[AMSYSCO News]]></category>
		<category><![CDATA[anchor]]></category>
		<category><![CDATA[architecture]]></category>
		<category><![CDATA[construction]]></category>
		<category><![CDATA[contractor]]></category>
		<category><![CDATA[ironworker]]></category>
		<category><![CDATA[Post Tensioning]]></category>
		<category><![CDATA[Post-Tensioning Institute]]></category>
		<category><![CDATA[stressing]]></category>

		<guid isPermaLink="false">http://www.amsyscoinc.com/blog/?p=1725</guid>
		<description><![CDATA[The following educational presentation is targeted towards General and Concrete Contractors interested in utilizing Post-Tensioned Concrete. <span style="color:#777"> . . . &#8594; Read More: <a href="http://www.amsyscoinc.com/blog/2010/10/23/informational-presentation-for-contractors/">Informational Presentation about Post-Tensioned Concrete for Contractors</a></span>]]></description>
			<content:encoded><![CDATA[<p>The following educational presentation is targeted towards General and Concrete Contractors interested in utilizing Post-Tensioned Concrete.</p>
<p>Please contact AMSYSCO at 630-296-8383 or at info@amsyscoinc.com to find out how we can help you with your construction project.</p>
<div id="__ss_5540649" style="width: 425px;"><strong><a class="vt-p" title="Post-Tension Concrete - Info session for Contractors" href="http://www.slideshare.net/amsysco/posttension-concrete-info-session-for-contractors">Post-Tension Concrete &#8211; Info session for Contractors</a></strong><object id="__sse5540649" width="425" height="355" classid="clsid:d27cdb6e-ae6d-11cf-96b8-444553540000" codebase="http://download.macromedia.com/pub/shockwave/cabs/flash/swflash.cab#version=6,0,40,0"><param name="allowFullScreen" value="true" /><param name="allowScriptAccess" value="always" /><param name="src" value="http://static.slidesharecdn.com/swf/ssplayer2.swf?doc=amsysco-contractorinfosession-101023181500-phpapp02&amp;stripped_title=posttension-concrete-info-session-for-contractors&amp;userName=amsysco" /><param name="allowfullscreen" value="true" /><param name="allowscriptaccess" value="always" /><embed id="__sse5540649" width="425" height="355" type="application/x-shockwave-flash" src="http://static.slidesharecdn.com/swf/ssplayer2.swf?doc=amsysco-contractorinfosession-101023181500-phpapp02&amp;stripped_title=posttension-concrete-info-session-for-contractors&amp;userName=amsysco" allowFullScreen="true" allowScriptAccess="always" allowfullscreen="true" allowscriptaccess="always" /></object></p>
<div style="padding: 5px 0 12px;">View more <a class="vt-p" href="http://www.slideshare.net/">presentations</a> from <a class="vt-p" href="http://www.slideshare.net/amsysco">Amsysco, Inc.</a>.</div>
</div>
<p>Outline of Presentation:</p>
<ol>
<li>Introduction to Post-Tension</li>
<li>Components of Post-Tension</li>
<li>Construction Team</li>
<li>Submittals</li>
<li>Pre-Installation</li>
<li>Installation Management</li>
<li>Post-Concrete Placement</li>
<li>Troubleshooting</li>
</ol>
<p>Download slides here =&gt; <a class="vt-p" href="http://www.amsyscoinc.com/blog/wp-content/uploads/2010/10/AMSYSCO-Contractor-info-session.pdf">AMSYSCO &#8211; Contractor info session</a> (PDF, 3MB).</p>
<p>- Neel Khosa, Vice President, AMSYSCO</p>
<p>____________________________________________</p>
<div style="text-align: left;"><strong>Copyright © 2010 by </strong><a class="vt-p" onclick="pageTracker._trackPageview('/outbound/article/bit.ly');" href="http://bit.ly/1tEis" target="_blank"><strong>AMSYSCO, Inc.</strong></a><strong> All rights reserved.</strong></div>
<div style="text-align: left;"><strong> </strong><br />
<strong> </strong></div>
]]></content:encoded>
			<wfw:commentRss>http://www.amsyscoinc.com/blog/2010/10/23/informational-presentation-for-contractors/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Diagram of Post Tensioning Slab</title>
		<link>http://www.amsyscoinc.com/blog/2010/09/14/diagram-of-post-tensioning-slab/</link>
		<comments>http://www.amsyscoinc.com/blog/2010/09/14/diagram-of-post-tensioning-slab/#comments</comments>
		<pubDate>Tue, 14 Sep 2010 20:55:24 +0000</pubDate>
		<dc:creator>nkhosa</dc:creator>
				<category><![CDATA[Post Tension]]></category>
		<category><![CDATA[anchor]]></category>
		<category><![CDATA[construction]]></category>
		<category><![CDATA[drawings]]></category>
		<category><![CDATA[Post Tensioning]]></category>
		<category><![CDATA[stressing]]></category>
		<category><![CDATA[tendon]]></category>

		<guid isPermaLink="false">http://www.amsyscoinc.com/blog/?p=1632</guid>
		<description><![CDATA[This is diagram of a post-tensioned concrete slab used in residential and commercial applications. <span style="color:#777"> . . . &#8594; Read More: <a href="http://www.amsyscoinc.com/blog/2010/09/14/diagram-of-post-tensioning-slab/">Diagram of Post Tensioning Slab</a></span>]]></description>
			<content:encoded><![CDATA[<div id="attachment_1664" class="wp-caption aligncenter" style="width: 610px"><a class="vt-p" href="http://www.amsyscoinc.com/blog/wp-content/uploads/2010/08/Post-Tension-Slab.jpg"><img class="size-full wp-image-1664" title="Post-Tension Slab" src="http://www.amsyscoinc.com/blog/wp-content/uploads/2010/08/Post-Tension-Slab.jpg" alt="" width="600" height="320" /></a><p class="wp-caption-text">Post-Tension Slab</p></div>
<p>Your typical Unbonded Post-Tensioned concrete slab will require the following items:</p>
<ol>
<li>Post-Tensioning Tendon</li>
<li>Anchorage Devices (at stressing, intermediate, fixed ends)</li>
<li>Reusable Pocket Formers (at stressing ends)</li>
<li>Split Pocket Formers (at intermediate ends)</li>
<li>Wedges (at stressing, intermediate, fixed ends)</li>
<li>Stressing Equipment (jack, pump, gauge)</li>
</ol>
<p>The <a class="vt-p" href="http://www.amsyscoinc.com/products/encapsulated.php" target="_blank">encapsulated </a>post-tension system requires additional corrosion-protection than the non-encapsulated post-tension system.</p>
<p>- Neel Khosa, Vice President, AMSYSCO</p>
<p>____________________________________________</p>
<div style="text-align: left;"><strong>Copyright © 2010 by </strong><a class="vt-p" onclick="pageTracker._trackPageview('/outbound/article/bit.ly');" href="http://bit.ly/1tEis" target="_blank"><strong>AMSYSCO, Inc.</strong></a><strong> All rights reserved.</strong></div>
]]></content:encoded>
			<wfw:commentRss>http://www.amsyscoinc.com/blog/2010/09/14/diagram-of-post-tensioning-slab/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Material Properties of Post-Tension Strands</title>
		<link>http://www.amsyscoinc.com/blog/2010/01/29/material-properties-of-post-tension-strands/</link>
		<comments>http://www.amsyscoinc.com/blog/2010/01/29/material-properties-of-post-tension-strands/#comments</comments>
		<pubDate>Sat, 30 Jan 2010 04:05:16 +0000</pubDate>
		<dc:creator>rkhosa</dc:creator>
				<category><![CDATA[Design Issues]]></category>
		<category><![CDATA[Post Tension]]></category>
		<category><![CDATA[american concrete institute]]></category>
		<category><![CDATA[concrete]]></category>
		<category><![CDATA[elongation]]></category>
		<category><![CDATA[force]]></category>
		<category><![CDATA[Post-Tensioning Institute]]></category>
		<category><![CDATA[stressing]]></category>
		<category><![CDATA[tendon]]></category>

		<guid isPermaLink="false">http://www.amsyscoinc.com/blog/?p=897</guid>
		<description><![CDATA[The following is a list of basic formulas for 270 ksi, 7-wire Prestressing steel strand (per ASTM-A416) used in Post-Tensioned concrete. <span style="color:#777"> . . . &#8594; Read More: <a href="http://www.amsyscoinc.com/blog/2010/01/29/material-properties-of-post-tension-strands/">Material Properties of Post-Tension Strands</a></span>]]></description>
			<content:encoded><![CDATA[<p>The following is a list of basic formulas for 270 ksi, 7-wire Prestressing steel strand (per <a class="vt-p" href="http://www.astm.org/Standards/A416.htm" target="_blank">ASTM-A416</a>) used in Post-Tensioned concrete.</p>
<p style="text-align: center;">_______________________________</p>
<p><em>Assume 0.5&#8243; diameter strand has cross-sectional area of 0.153 sq.in. and weight of 0.525 lbs/ft.</em></p>
<p><em>Assume 0.6&#8243; diameter strand has cross-sectional area of 0.217 sq.in. and weight of 0.740 lbs/ft.</em></p>
<p style="text-align: center;">_______________________________</p>
<p><strong><span style="color: #000000;">Minimum Ultimate Tensile Strength (MUTS) = (Grade of Steel) x (Cross-Sectional Area)</span></strong></p>
<p style="text-align: center;">0.5&#8243; inch diameter = (270 ksi) x (0.153 sq.in.) = 41.3 kips</p>
<p style="text-align: center;">0.6&#8243; inch diameter = (270 ksi) x (0.217 sq.in.) = 58.6 kips</p>
<p style="text-align: center;">_______________________________</p>
<p style="text-align: center;"><strong>Minimum Yield Strength = 90% of MUTS = MUTS x 0.90 </strong><em>(per <a class="vt-p" href="http://www.astm.org/Standards/A416.htm" target="_blank">ASTM-A416</a></em><em>)</em></p>
<p style="text-align: center;">0.5&#8243; inch diameter = (41.3 kips) x (0.90) = 37.2 kips</p>
<p style="text-align: center;">0.6&#8243; inch diameter = (58.6 kips) x (0.90) = 52.7 kips</p>
<p style="text-align: center;">_______________________________</p>
<p><strong>Jacking Force = 80% of MUTS = MUTS x 0.80 </strong><em>(per ACI Code)</em></p>
<p style="text-align: center;">0.5&#8243; inch diameter = (41.3 kips) x (0.80) = 33.0 kips</p>
<p style="text-align: center;">0.6&#8243; inch diameter = (58.6 kips) x (0.80) = 46.9 kips</p>
<p style="text-align: left;">&#8220;Jacking Force&#8221; is the force that tendons are stressed to.</p>
<p style="text-align: center;">_______________________________</p>
<p><strong>Allowable Initial Force = (Jacking Force) minus (Short-Term Losses) = 70% of MUTS = MUTS x 0.70 </strong><em>(per <a class="vt-p" href="http://www.concrete.org/bookstorenet/ProductDetail.aspx?ItemID=31808" target="_blank">ACI-318</a></em><em>)</em></p>
<p>Short-Term Losses include:</p>
<ol>
<li>Angular Profile of Tendon</li>
<li>Horizontal sweeps in Tendon</li>
<li>Wedge-Seating (typically 0.25 inch)</li>
<li>Wobble due to installation (<a class="vt-p" href="http://www.amsyscoinc.com/blog/2009/10/07/video-field-friction-test-for-post-tension-tendons/" target="_blank">CLICK HERE</a> to view the video on how to calculate Angular and Wobble Coefficients in unbonded post-tensioning tendons.)</li>
</ol>
<p style="text-align: center;">0.5&#8243; inch diameter = (41.3 kips) x (0.70) = 28.9 kips</p>
<p style="text-align: center;">0.6&#8243; inch diameter = (58.6 kips) x (0.70) = 41.0 kips</p>
<p style="text-align: left;">&#8220;Initial Force&#8221; is the force at the anchorage after the wedges are seated and stressing jack is removed.  The calculated values above are approximate since the actual short-term losses may differ from the theoretical values.</p>
<p style="text-align: center;">_______________________________</p>
<p style="text-align: left;"><strong>Final Force = (Initial Force) minus (Long-Term Losses)</strong></p>
<p style="text-align: left;">Long-Term Losses include:</p>
<ol>
<li>Creep of concrete (permanent deflection due application of constant load)</li>
<li>Elastic Shortening of concrete</li>
<li>Relaxation of steel prestressing strand</li>
<li>Shrinkage of concrete during curing</li>
</ol>
<p style="text-align: center;">0.5&#8243; inch diameter = approx 26.9 kips</p>
<p style="text-align: center;">0.6&#8243; inch diameter = approx. 38.1 kips</p>
<p style="text-align: left;">&#8220;Final Force&#8221; is the force at the anchorage after the long-term losses are accounted for.  The calculated values above are approximate since the actual long-term losses may differ from the theoretical values.</p>
<p style="text-align: center;">_______________________________</p>
<p><strong>Average Tendon Elongation (approx.) = (P x L) / (A x E)</strong></p>
<p style="padding-left: 30px;">P = Prestress jacking force (70% of MUTS)</p>
<p style="padding-left: 30px;">L = Length of steel (inches)</p>
<p style="padding-left: 30px;">A = Cross-Sectional Area of steel (sq.in.) on mill certificates</p>
<p style="padding-left: 30px;">E = Modulus of Elasticity of steel (ksi) on mill certificates</p>
<p>For example, using a 100-foot tendon (L = 100 x 12 inches) with Modulus of Elasticity of 28,500 ksi.</p>
<p style="text-align: center;">0.5&#8243; inch diameter = (28.9 kips x 1,200 inches) / (0.153 sq.in. x 28,500 ksi) = 7.95 inches</p>
<p style="text-align: center;">0.6&#8243; inch diameter = (41.0 kips x 1,200 inches) / (0.217 sq.in. x 28,500 ksi) = 7.95 inches</p>
<p style="text-align: center;">***Notice that the 0.5&#8243; and 0.6&#8243; have the same Avg. Elongation***</p>
<p style="text-align: center;">_______________________________</p>
<p><a class="vt-p" href="http://www.post-tensioning.org/" target="_blank">Post-Tensioning Institute</a> recommends an allowable elongation range of plus/minus 7% of the Average Tendon Elongation for unbonded post-tensioning tendons.</p>
<p><strong>Min. Allowable Elongation = 93% of Avg. Elongation = 0.93 x (Avg.El.)</strong></p>
<p><strong>Max. Allowable Elongation = 107% of Avg. Elongation = 1.07 x (Avg.El.)</strong></p>
<p>If we use the same 100-foot tendon with average elongation of 7.95 inches, then Min.El. = 0.93 x 7.95 inches = 7.40 inches and Max.El. = 1.07 x 7.95 inches = 8.51 inches.</p>
<p>- Rattan Khosa, President, AMSYSCO</p>
<div>____________________________________________</div>
<div><strong>Copyright © 2010 by </strong><a class="vt-p" onclick="pageTracker._trackPageview('/outbound/article/bit.ly');" href="http://bit.ly/1tEis" target="_blank"><strong>AMSYSCO, Inc.</strong></a><strong> All rights reserved.</strong></div>
]]></content:encoded>
			<wfw:commentRss>http://www.amsyscoinc.com/blog/2010/01/29/material-properties-of-post-tension-strands/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Download:  Stressing Elongation Form</title>
		<link>http://www.amsyscoinc.com/blog/2009/11/11/elongation-stressing-record/</link>
		<comments>http://www.amsyscoinc.com/blog/2009/11/11/elongation-stressing-record/#comments</comments>
		<pubDate>Wed, 11 Nov 2009 21:01:53 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Field Issues]]></category>
		<category><![CDATA[downloads]]></category>
		<category><![CDATA[elongation]]></category>
		<category><![CDATA[stressing]]></category>
		<category><![CDATA[Unbonded]]></category>

		<guid isPermaLink="false">http://www.amsyscoinc.com/blog/?p=693</guid>
		<description><![CDATA[The form is used for recording elongations for Unbonded Post Tensioning. <span style="color:#777"> . . . &#8594; Read More: <a href="http://www.amsyscoinc.com/blog/2009/11/11/elongation-stressing-record/">Download:  Stressing Elongation Form</a></span>]]></description>
			<content:encoded><![CDATA[<p>Please download AMSYSCO&#8217;s &#8216;Master Stressing Record&#8217; <a class="vt-p" href="http://www.amsyscoinc.com/blog/wp-content/uploads/2011/10/Stressing-Record.pdf" target="_blank">(Click here to download)</a>.  The form is used for recording elongations for Unbonded Post Tensioning.</p>
<p>This form is for Inspectors and Installers certified by the <a class="vt-p" href="http://www.post-tensioning.org" target="_blank">Post Tensioning Institute</a>.  Check out our <a class="vt-p" href="http://www.amsyscoinc.com/blog/2009/08/03/archives266/" target="_blank">VIDEO </a> for the basics in stressing post tensioning tendons.</p>
<p><em>*** Updated (10/21/2011) &#8211; In response to industry demand, we have updated our elongation report to include.  The updates include columns to track whether the tendon tail has been cut properly, the encapsulated anchor has been capped (if applicable) and the stressing pocket has been grouted.</em></p>
<p style="line-height: 14.25pt;"><span style="font-family: 'Georgia', 'serif'; color: black; font-size: 10pt;">Copyright © 2009 by <a class="vt-p" onclick="pageTracker._trackPageview('/outbound/article/bit.ly');" href="http://bit.ly/1tEis" target="_blank">AMSYSCO, Inc.</a> All rights reserved.</span></p>
]]></content:encoded>
			<wfw:commentRss>http://www.amsyscoinc.com/blog/2009/11/11/elongation-stressing-record/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Unbonded Post Tensioning &#8211; Preconstruction Checklist</title>
		<link>http://www.amsyscoinc.com/blog/2009/09/21/preconstruction-post-tensioning/</link>
		<comments>http://www.amsyscoinc.com/blog/2009/09/21/preconstruction-post-tensioning/#comments</comments>
		<pubDate>Mon, 21 Sep 2009 16:30:51 +0000</pubDate>
		<dc:creator>rkhosa</dc:creator>
				<category><![CDATA[Design Issues]]></category>
		<category><![CDATA[Field Issues]]></category>
		<category><![CDATA[Post Tension]]></category>
		<category><![CDATA[checklist]]></category>
		<category><![CDATA[concrete]]></category>
		<category><![CDATA[construction]]></category>
		<category><![CDATA[contractor]]></category>
		<category><![CDATA[drawings]]></category>
		<category><![CDATA[inspector]]></category>
		<category><![CDATA[ironworker]]></category>
		<category><![CDATA[Post Tensioning]]></category>
		<category><![CDATA[Pour Sequence]]></category>
		<category><![CDATA[stressing]]></category>
		<category><![CDATA[Unbonded]]></category>

		<guid isPermaLink="false">http://www.amsyscoinc.com/blog/?p=622</guid>
		<description><![CDATA[The following is a preconstruction checklist for General Contractors / Construction Managers that can be used for Unbonded Post Tensioning projects. <span style="color:#777"> . . . &#8594; Read More: <a href="http://www.amsyscoinc.com/blog/2009/09/21/preconstruction-post-tensioning/">Unbonded Post Tensioning &#8211; Preconstruction Checklist</a></span>]]></description>
			<content:encoded><![CDATA[<p>The following is a preconstruction checklist for General Contractors / Construction Managers that can be used for Unbonded Post Tensioning projects.  It has saved AMSYSCO, Inc. and its Clients from costly errors, revisions, delays and problems.  <em>These checklist(s) are not inclusive and are only meant to help post tensioned concrete projects</em>.</p>
<p><span style="text-decoration: underline;">Checklist – BEFORE Post Tensioning shop drawings are started</span></p>
<p>1. Does the Post Tensioning Supplier have the latest and complete set of <strong>Structural Drawings</strong> and/or Architectural elevations/floor Plans?</p>
<p>2. Does the Post Tensioning Supplier have the latest <strong>Post Tensioning specifications</strong> and/or Barrier Cable specifications?</p>
<p>3. Has the <strong>pour sequence</strong> been finalized showing pour numbers, construction joints and/or pour strips?</p>
<p>4. Are there any <strong>restrictions to stressing</strong> tendons due to existing buildings, shear/elevator/stair walls or space limitations?</p>
<p>5. Have the major <strong>slab openings</strong> been coordinated and approved by the Structural Engineer?</p>
<p>6. Are <strong>structural CAD Files</strong> available to save time on detailing shop drawings?</p>
<p>7. For residential/office buildings:  Are <strong>MEP CAD Files</strong> available for coordination with Post Tensioning drawings?</p>
<p><span style="text-decoration: underline;">Checklist – BEFORE Post Tensioning is awarded</span></p>
<p>1. Does the jobsite have a copy of the Post Tensioning Institute’s “<a class="vt-p" href="http://post-tensioning.org/product/x_cTPkl4GcmEY2lkPT/Construction%20&amp;%20Repair" target="_blank">Field Procedures Manual for Unbonded Single Strand Tendons</a>” (3<sup>rd</sup> Edition is current as of 2009)?</p>
<p>2. Does the Post Tensioning <strong>Installer</strong> have an individual who is currently certified under the Post Tensioning Institute’s “<a class="vt-p" href="http://post-tensioning.org/certification_program.php#SUPERSTRUCTURE" target="_blank">Level 2 Field Certification for Superstructure Ironworkers</a>” program (or approved equal certification program)?  Are the other members of the installation crew certified under the Post-Tensioning Institute&#8217;s &#8220;<a class="vt-p" href="http://post-tensioning.org/certification_program.php#level1" target="_blank">Level 1 Field Fundamentals of Installation</a>&#8221; program?</p>
<p>3. Does the Post Tensioning <strong>Inspector</strong> have an individual who is currently certified under the Post Tensioning Institute’s “<a class="vt-p" href="http://post-tensioning.org/certification_program.php#INSPECTOR" target="_blank">Level 2 Field Certification for Inspector</a>” program (or approved equal certification program)?</p>
<p>4. Is the Post Tensioning <strong>Supplier</strong> certified under the Post Tensioning Institute’s “<a class="vt-p" href="http://post-tensioning.org/cert_plant.php" target="_blank">Plant Certification</a>” program?</p>
<p>5. Does the Post Tensioning <strong>Installer</strong> have an individual with experience with hydraulic stressing equipment for Post Tensioning?  This individual should have a <a class="vt-p" href="http://post-tensioning.org/category/x_zEY2l3kPT/Online%20Re-Certification" target="_blank">current</a> PTI-Certification (Level 2 Ironworker), be onsite and have a proven track record of working with stressing equipment.  Safety is priority one.</p>
<p>- Rattan Khosa, AMSYSCO</p>
<p style="line-height: 14.25pt;"><span style="font-size: 10pt; color: black; font-family: 'Georgia','serif';">Copyright © 2009 by <a class="vt-p" onclick="pageTracker._trackPageview('/outbound/article/bit.ly');" href="http://bit.ly/1tEis" target="_blank">AMSYSCO, Inc.</a> All rights reserved.</span></p>
]]></content:encoded>
			<wfw:commentRss>http://www.amsyscoinc.com/blog/2009/09/21/preconstruction-post-tensioning/feed/</wfw:commentRss>
		<slash:comments>1</slash:comments>
		</item>
		<item>
		<title>VIDEO: Stressing Post-Tensioning Tendons</title>
		<link>http://www.amsyscoinc.com/blog/2009/08/03/archives266/</link>
		<comments>http://www.amsyscoinc.com/blog/2009/08/03/archives266/#comments</comments>
		<pubDate>Tue, 04 Aug 2009 00:25:23 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Field Issues]]></category>
		<category><![CDATA[Post Tension]]></category>
		<category><![CDATA[Video]]></category>
		<category><![CDATA[Post Tensioning]]></category>
		<category><![CDATA[stressing]]></category>
		<category><![CDATA[YouTube Video]]></category>

		<guid isPermaLink="false">http://www.amsyscoinc.com/blog/?p=266</guid>
		<description><![CDATA[This informational video shows some highlights of Stressing Unbonded Post-Tensioning Tendons. The video follows Post-Tensioning Institute's Field Procedures Manual for Unbonded Tendons. <span style="color:#777"> . . . &#8594; Read More: <a href="http://www.amsyscoinc.com/blog/2009/08/03/archives266/">VIDEO: Stressing Post-Tensioning Tendons</a></span>]]></description>
			<content:encoded><![CDATA[<div class="mceTemp mceIEcenter">This informational video shows some highlights of Stressing Unbonded Post-Tensioning Tendons. The video follows <a class="vt-p" href="http://www.post-tensioning.org/Uploads/Book%20Order%20Form.pdf" target="_blank">Post-Tensioning Institute&#8217;s Field Procedures Manual for Unbonded Tendons</a>.</div>
<p><object classid="clsid:d27cdb6e-ae6d-11cf-96b8-444553540000" width="560" height="340" codebase="http://download.macromedia.com/pub/shockwave/cabs/flash/swflash.cab#version=6,0,40,0"><param name="allowFullScreen" value="true" /><param name="allowscriptaccess" value="always" /><param name="src" value="http://www.youtube.com/v/vTbiVhg7_08&amp;hl=en&amp;fs=1&amp;" /><param name="allowfullscreen" value="true" /><embed type="application/x-shockwave-flash" width="560" height="340" src="http://www.youtube.com/v/vTbiVhg7_08&amp;hl=en&amp;fs=1&amp;" allowscriptaccess="always" allowfullscreen="true"></embed></object></p>
<p style="line-height: 14.25pt;"><span style="font-size: 10pt; color: black; font-family: 'Georgia','serif';">Copyright © 2009 by <a class="vt-p" onclick="pageTracker._trackPageview('/outbound/article/bit.ly');" href="http://bit.ly/1tEis" target="_blank">AMSYSCO, Inc.</a> All rights reserved.</span></p>
]]></content:encoded>
			<wfw:commentRss>http://www.amsyscoinc.com/blog/2009/08/03/archives266/feed/</wfw:commentRss>
		<slash:comments>1</slash:comments>
		</item>
	</channel>
</rss>