<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>AMSYSCO Post Tension Blog &#187; force</title>
	<atom:link href="http://www.amsyscoinc.com/blog/tag/force/feed/" rel="self" type="application/rss+xml" />
	<link>http://www.amsyscoinc.com/blog</link>
	<description>Post-Tensioning for Concrete Contractors, Structural Engineers and Architects</description>
	<lastBuildDate>Thu, 19 Jan 2012 20:45:35 +0000</lastBuildDate>
	<language>en</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
	<generator>http://wordpress.org/?v=3.3.1</generator>
		<item>
		<title>Material Properties of Post-Tension Strands</title>
		<link>http://www.amsyscoinc.com/blog/2010/01/29/material-properties-of-post-tension-strands/</link>
		<comments>http://www.amsyscoinc.com/blog/2010/01/29/material-properties-of-post-tension-strands/#comments</comments>
		<pubDate>Sat, 30 Jan 2010 04:05:16 +0000</pubDate>
		<dc:creator>rkhosa</dc:creator>
				<category><![CDATA[Design Issues]]></category>
		<category><![CDATA[Post Tension]]></category>
		<category><![CDATA[american concrete institute]]></category>
		<category><![CDATA[concrete]]></category>
		<category><![CDATA[elongation]]></category>
		<category><![CDATA[force]]></category>
		<category><![CDATA[Post-Tensioning Institute]]></category>
		<category><![CDATA[stressing]]></category>
		<category><![CDATA[tendon]]></category>

		<guid isPermaLink="false">http://www.amsyscoinc.com/blog/?p=897</guid>
		<description><![CDATA[The following is a list of basic formulas for 270 ksi, 7-wire Prestressing steel strand (per ASTM-A416) used in Post-Tensioned concrete. <span style="color:#777"> . . . &#8594; Read More: <a href="http://www.amsyscoinc.com/blog/2010/01/29/material-properties-of-post-tension-strands/">Material Properties of Post-Tension Strands</a></span>]]></description>
			<content:encoded><![CDATA[<p>The following is a list of basic formulas for 270 ksi, 7-wire Prestressing steel strand (per <a class="vt-p" href="http://www.astm.org/Standards/A416.htm" target="_blank">ASTM-A416</a>) used in Post-Tensioned concrete.</p>
<p style="text-align: center;">_______________________________</p>
<p><em>Assume 0.5&#8243; diameter strand has cross-sectional area of 0.153 sq.in. and weight of 0.525 lbs/ft.</em></p>
<p><em>Assume 0.6&#8243; diameter strand has cross-sectional area of 0.217 sq.in. and weight of 0.740 lbs/ft.</em></p>
<p style="text-align: center;">_______________________________</p>
<p><strong><span style="color: #000000;">Minimum Ultimate Tensile Strength (MUTS) = (Grade of Steel) x (Cross-Sectional Area)</span></strong></p>
<p style="text-align: center;">0.5&#8243; inch diameter = (270 ksi) x (0.153 sq.in.) = 41.3 kips</p>
<p style="text-align: center;">0.6&#8243; inch diameter = (270 ksi) x (0.217 sq.in.) = 58.6 kips</p>
<p style="text-align: center;">_______________________________</p>
<p style="text-align: center;"><strong>Minimum Yield Strength = 90% of MUTS = MUTS x 0.90 </strong><em>(per <a class="vt-p" href="http://www.astm.org/Standards/A416.htm" target="_blank">ASTM-A416</a></em><em>)</em></p>
<p style="text-align: center;">0.5&#8243; inch diameter = (41.3 kips) x (0.90) = 37.2 kips</p>
<p style="text-align: center;">0.6&#8243; inch diameter = (58.6 kips) x (0.90) = 52.7 kips</p>
<p style="text-align: center;">_______________________________</p>
<p><strong>Jacking Force = 80% of MUTS = MUTS x 0.80 </strong><em>(per ACI Code)</em></p>
<p style="text-align: center;">0.5&#8243; inch diameter = (41.3 kips) x (0.80) = 33.0 kips</p>
<p style="text-align: center;">0.6&#8243; inch diameter = (58.6 kips) x (0.80) = 46.9 kips</p>
<p style="text-align: left;">&#8220;Jacking Force&#8221; is the force that tendons are stressed to.</p>
<p style="text-align: center;">_______________________________</p>
<p><strong>Allowable Initial Force = (Jacking Force) minus (Short-Term Losses) = 70% of MUTS = MUTS x 0.70 </strong><em>(per <a class="vt-p" href="http://www.concrete.org/bookstorenet/ProductDetail.aspx?ItemID=31808" target="_blank">ACI-318</a></em><em>)</em></p>
<p>Short-Term Losses include:</p>
<ol>
<li>Angular Profile of Tendon</li>
<li>Horizontal sweeps in Tendon</li>
<li>Wedge-Seating (typically 0.25 inch)</li>
<li>Wobble due to installation (<a class="vt-p" href="http://www.amsyscoinc.com/blog/2009/10/07/video-field-friction-test-for-post-tension-tendons/" target="_blank">CLICK HERE</a> to view the video on how to calculate Angular and Wobble Coefficients in unbonded post-tensioning tendons.)</li>
</ol>
<p style="text-align: center;">0.5&#8243; inch diameter = (41.3 kips) x (0.70) = 28.9 kips</p>
<p style="text-align: center;">0.6&#8243; inch diameter = (58.6 kips) x (0.70) = 41.0 kips</p>
<p style="text-align: left;">&#8220;Initial Force&#8221; is the force at the anchorage after the wedges are seated and stressing jack is removed.  The calculated values above are approximate since the actual short-term losses may differ from the theoretical values.</p>
<p style="text-align: center;">_______________________________</p>
<p style="text-align: left;"><strong>Final Force = (Initial Force) minus (Long-Term Losses)</strong></p>
<p style="text-align: left;">Long-Term Losses include:</p>
<ol>
<li>Creep of concrete (permanent deflection due application of constant load)</li>
<li>Elastic Shortening of concrete</li>
<li>Relaxation of steel prestressing strand</li>
<li>Shrinkage of concrete during curing</li>
</ol>
<p style="text-align: center;">0.5&#8243; inch diameter = approx 26.9 kips</p>
<p style="text-align: center;">0.6&#8243; inch diameter = approx. 38.1 kips</p>
<p style="text-align: left;">&#8220;Final Force&#8221; is the force at the anchorage after the long-term losses are accounted for.  The calculated values above are approximate since the actual long-term losses may differ from the theoretical values.</p>
<p style="text-align: center;">_______________________________</p>
<p><strong>Average Tendon Elongation (approx.) = (P x L) / (A x E)</strong></p>
<p style="padding-left: 30px;">P = Prestress jacking force (70% of MUTS)</p>
<p style="padding-left: 30px;">L = Length of steel (inches)</p>
<p style="padding-left: 30px;">A = Cross-Sectional Area of steel (sq.in.) on mill certificates</p>
<p style="padding-left: 30px;">E = Modulus of Elasticity of steel (ksi) on mill certificates</p>
<p>For example, using a 100-foot tendon (L = 100 x 12 inches) with Modulus of Elasticity of 28,500 ksi.</p>
<p style="text-align: center;">0.5&#8243; inch diameter = (28.9 kips x 1,200 inches) / (0.153 sq.in. x 28,500 ksi) = 7.95 inches</p>
<p style="text-align: center;">0.6&#8243; inch diameter = (41.0 kips x 1,200 inches) / (0.217 sq.in. x 28,500 ksi) = 7.95 inches</p>
<p style="text-align: center;">***Notice that the 0.5&#8243; and 0.6&#8243; have the same Avg. Elongation***</p>
<p style="text-align: center;">_______________________________</p>
<p><a class="vt-p" href="http://www.post-tensioning.org/" target="_blank">Post-Tensioning Institute</a> recommends an allowable elongation range of plus/minus 7% of the Average Tendon Elongation for unbonded post-tensioning tendons.</p>
<p><strong>Min. Allowable Elongation = 93% of Avg. Elongation = 0.93 x (Avg.El.)</strong></p>
<p><strong>Max. Allowable Elongation = 107% of Avg. Elongation = 1.07 x (Avg.El.)</strong></p>
<p>If we use the same 100-foot tendon with average elongation of 7.95 inches, then Min.El. = 0.93 x 7.95 inches = 7.40 inches and Max.El. = 1.07 x 7.95 inches = 8.51 inches.</p>
<p>- Rattan Khosa, President, AMSYSCO</p>